PERFORMANCE GUIDELINES: 12. FLOORING
12.40 Adjacent Marble Units or Ceramic Tile Surfaces Installed at Different Elevations
Acceptable Performance/Condition
Considering the texture and intended aesthetic application of the finished surface, adjacent marble units and/or ceramic tiles shall be installed generally flush. Adjoining tiles that exceed 3 mm (1/8") in variance are not acceptable.
Some floor tiles are designed with irregular finished surfaces, which may exaggerate the aesthetic appearance of the condition.
Warranty Coverage
- 12 months In-Home
- 15 months Common Property
Claim Response
Tiles not meeting the Acceptable Performance/Condition are to be rectified.
Where repairs are made, an exact match of colour, finish, grain, sheen or texture may not be possible.
Maintenance Tip
No maintenance tips available

Documents
No documents available