PERFORMANCE GUIDELINES: 15. MULTI-UNIT

15.9 Finished Concrete Ceiling Cracks

Acceptable Performance/Condition

Applicable to high-rises.

Cracks resulting from normal shrinkage are acceptable; cracks in excess of 3mm (1/8") in width are not acceptable.

Concrete ceilings naturally crack during curing due to shrinkage.

Actual crack widths shall be determined using a suitable measuring device inserted inside the crack.

Warranty Coverage

  • 12 months In-Home
  • 15 months Common Property

Claim Response

Cracks not meeting the Acceptable Performance/Condition shall be rectified.

Where repairs are necessary, colour and/or texture may not match the surrounding finish.

Maintenance Tip

No maintenance tips available