PERFORMANCE GUIDELINES: 11. CABINETS AND COUNTERTOPS

11.10 Laminated Countertop Seam Width Excessive

Acceptable Performance/Condition

Laminated countertop seams shall be installed tight; gaps should not exceed 1.5mm (1/16”).

Warranty Coverage

  • 12 months In-Home
  • 15 months Common Property

Damage resulting from maintenance not conducted in keeping with maintenance documentation provided to the owner by the warranty provider or builder is not covered under warranty.

Claim Response

Countertops not meeting the Acceptable Performance/Condition are to be rectified.

Typically, seam gaps within 1.5mm (1/16”) in width can be sealed with appropriate seam filler. Where repairs are made, an exact match of colour, finish, grain, sheen or texture may not be possible.

Maintenance Tip

Do not allow water to remain on countertop joints.

The gap between adjacent surfaces (i.e. countertop and ceramic tile backsplash) should be sealed to prevent water entry along the junction.