PERFORMANCE GUIDELINES: 1. FOUNDATION/BASEMENT

1.4 Exposed Interior Concrete Floor Slabs Are Uneven

Acceptable Performance/Condition

Exposed interior concrete floors shall not have bumps, ridges or depressions exceeding 12 mm (1/2”) within a 3 m (10') specified plane.

Concrete floors sloped to provide drainage is not considered to be a defect.

Crawl space skim coats are excluded from this guideline.

Warranty Coverage

  • 12 months In-Home
  • 15 month Common Property

Claim Response

Floor slabs not meeting the Acceptable Performance/Condition must be rectified.

Repairs may include grinding, applying a topping or other industry acceptable methods.

The colour, finish or texture of a repaired area may not match the surrounding concrete.