PERFORMANCE GUIDELINES: 15. MULTI-UNIT
15.9 Finished Concrete Ceiling Cracks
Acceptable Performance/Condition
Applicable to high-rises.
Cracks resulting from normal shrinkage are acceptable; cracks in excess of 3mm (1/8") in width are not acceptable.
Concrete ceilings naturally crack during curing due to shrinkage.
Actual crack widths shall be determined using a suitable measuring device inserted inside the crack.
Warranty Coverage
- 12 months In-Home
- 15 months Common Property
Claim Response
Cracks not meeting the Acceptable Performance/Condition shall be rectified.
Where repairs are necessary, colour and/or texture may not match the surrounding finish.