PERFORMANCE GUIDELINES: 4. EXTERIOR FINISHING

4.2 Wood, Hardboard or Panel-Type Siding Joints Not Tight

Acceptable Performance/Condition

Wood or hardboard or other panel-type siding shall be installed in accordance with the Building Code and manufacturer’s requirements with gaps at joints to allow for expansion as required.

Gaps at joints or transitions may allow for expansion and help prevent buckling.

Joints shall be suitably protected to prevent water penetration. Caulking, slip sheets, back-flashing or attaching battens over the joints are ways to protect the joints from water penetration.

Warranty Coverage

  • 12 months In-Home
  • 15 months Common Property
  • 2 years Cladding Detachment or Material Damage

Normal shrinkage of materials caused by drying after construction is not covered under warranty.

Defects in materials, work or design supplied by the owner and damage resulting from maintenance not conducted in keeping with maintenance documentation provided to the owner by the warranty provider or builder are not covered under warranty.

Claim Response

Wood or hardboard or other panel-type siding joints not meeting the Acceptable Performance/Condition are to be rectified.

Where repairs are required, colour, finish, grain, sheen or texture may not have an exact match.

Seasonal conditions may affect the timing of repairs.

Maintenance Tip

Keep tree branches, shrubs and plants away from siding.