PERFORMANCE GUIDELINES: 1. FOUNDATION/BASEMENT

1.18 Sump Pump for Perimeter Drainage Has Failed

Acceptable Performance/Condition

The sump pump and piping shall perform as intended.

The pump and controls are considered plumbing and electrical fixtures

Warranty Coverage

  • 12 months In-Home
  • 15 months Common Property
  • 2 years Delivery and Distribution Systems (Electrical Wiring, Foundation Drainage Pipes)

Damage resulting from maintenance not conducted in keeping with maintenance documentation provided to the owner by the warranty provider or builder is not covered under warranty.

Claim Response

Sump systems not meeting Acceptable Performance/Condition must be rectified.

Maintenance Tip

Sumps, pumps and perimeter drainage need inspection, regular maintenance and cleaning. Most pump failures are caused by failure to maintain.

Access pipes or clean-outs are installed to allow the perimeter drain tile to be inspected and cleaned. The location of these clean-outs should be identified for future reference. Clean sediment from sumps and catch basins at least yearly.

If sump pump is used, ensure the motor and electrical supply is operational every spring.